LABORATORY TESTS ON CLAY

6. Test for fired water absorption

The degree of water absorption is the measure of the vitrification of a fired clay body. This is determined by the following procedure

  1. Make bars of 5X5X10 cm. Minimum 3 bars has to be made.
  2. Fire the bars and weigh the fired bars.
  3. Boil the fired bars in water for 2 hours.
  4. Dry the surface of the bar with a towel and weigh them again.
  5. Calculate the water absorption by using the following formula.

% Linear Water Absorption = ((Saturated Wt - Dry Wt)/Dry Wt)*100

To be contd…..